[Scegli Nazione]   Italia
You must have cookies enabled to get the best browsing experience on our website.
Learn how to enable cookies.



Amplificatore sezionatore





Guarda tutti i prodotti per tipologia: Amplificatore sezionatore


Prima PaginaPrevious Page1 - 10 ( di 20 ) Prossima PaginaUltima Pagina
Elementi per pagina:
ProdottoBreve descrizione
Amplificatore di commutazione
KCD2-SR-1.LB
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Amplificatore di commutazione
KCD2-SR-1.LB.SP
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Amplificatore di commutazione
KCD2-SR-2
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Amplificatore di commutazione
KCD2-SR-2.SP
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Conductivity Switch Amplifier
KFA5-ER-1.W.LB
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-1.5
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-1.6
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-2.W.LB
2-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA6-ER-1.W.LB
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Latching relay output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA6-ER-1.5
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Latching relay output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay
Prima PaginaPrevious Page1 - 10 ( di 20 ) Prossima PaginaUltima Pagina
Elementi per pagina:

Supporto online

Telefono ++39 039 62921
Fax ++39 039 6292 390