1 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
2 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
Fotocellula in miniatura a fascio singolo, ideale per l'installazione in telai e bordi, Circuito integrato, Alloggiamento plug-in per foro da 13 mm, Angolo di apertura ridotto, adatto per il montaggio a coppie, Varie frequenze per prevenire interferenze dovute alla prossimità, Forma costruttiva(S2): Cilindrico, liscio, Trasmettitore fotoelettrico: IRED, Tipo di luce: infrarosso, modulata , 880 nm, Tensione di esercizio: 10 ... 30 V DC, Tipo di circuito: Intervento in presenza di lucefa
Non disponibile per l'acquisto: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Non disponibile per l'acquisto: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Non disponibile per l'acquisto: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
GetanoverviewofPepperl+Fuchs' broadportfolioofHMIsystemsforprocessindustries ... areas. ThepowersuppliesareapprovedforZone1/21andZone2/22 (ATEXandIECEx) aswellasDiv. 2, Class I, IIandIII , andarealsosuitableforuse in harshconditions due totheirrobustanodizedaluminumhousings. Peripherals A broadrangeof ...
I thinclient con custodiaindustriale di Pepperl+Fuchs sono progettati per offrireun'affidabile e robustasoluzione di virtualizzazione in ambientiindustrialidifficili ... tramiteDisplayPorts e modalitàUSB-C alt2Risoluzione dello schermoUltraHD (4K) fino a 60Hz per i modernischermi di grandidimensioni3porteGigabitEthernetdedicateScopri di più sul BTC22BTC14: realizzato per installazioni di monitorquadrupli ...
Visita l'"hubsicurezzafunzionale" di Pepperl+Fuchs, dove potraitrovaredispositivivalutati in fatto di sicurezza per applicazioni di automazione di fabbrica, e anche accedere a utilistrumenti e brochure ... di una modifica della norma (EN1010-1:2004modificata in ENISO12643-4), l'interventodell'operatore in areepotenzialmentepericolose delle macchine per imballaggio deve essere evitato in futuro con PL d anzichéPLb al fine di garantire la massimaprotezione ...
Pepperl+Fuchsoffresoluzioni di identificazioneRFID per applicazioniindustriali nel campodell'automazione di fabbrica ... di controllo e cavi) e gamme di frequenza di usocomune (LF-HF-UHF), per rispondere alle esigenzespecifiche dei clienti. Altacompatibilità per una facileintegrazione I componentiRFID di Pepperl+Fuchs si adattano a quasi tutti i tipi di sistemi di controllo ...
I sensoriradarFMCWindustriali di Pepperl+Fuchs sono caratterizzati da un range di letturaelevato e sono ideali per l'integrazione in macchinemobili ... velocity" mode, ontheotherhand, theradarsensordetectstheobjectthatismovingthefastesttowardsorawayfromthesensor. ThismeasurementmodeeffectivelysupportsthemonitoringoftheAGV’strack, forexample. Integrazione Il valored'uso ...
Tecnologia di protezione contro le sovratensioni per l'industria dei processi di Pepperl+Fuchs ... maggioreefficienza, flessibilità e disponibilità per gli impianti di processo. Sistema di protezione contro le sovratensioniM-LB-2000 L' M-LB-2000offrefunzioni di base in una custodiacompatta: con una larghezza di soli6,2mm , riduce al minimo ...
Desideririlevarel'inclinazione senza errori per applicazionidinamiche? ScopriIMUF99 di Pepperl+Fuchs ... ° e adattabilesingolarmente. Dispositivo di misurazioneinerzialeF99 Come evitarevaloridell'angolo di inclinazioneerrati nelle applicazionidinamiche? Scopri come PeterSchmidt ha trovato la soluzioneideale. Ti sei mai chiesto come garantirevalori ...
Sia su strada che fuori strada, i sensoriutilizzati nelle apparecchiaturemobilidevonofunzionare in modo affidabile in condizionidifficiliPepperl+Fuchsoffreun'ampiagamma di sensori per le macchinemobili ... vari sensoricollegati. La CANriducenotevolmente le attività di cablaggio e fornisce una reteeconomica e duratura. Pepperl+Fuchsoffresensori ad ultrasuoni, radar e d'inclinazionenonchéencoderrotativi con interfacceCANJ1939 e CANopen per una facile ...
Pepperl+Fuchsoffreun'ampiagamma lungo l'interacatena del valoredell'idrogenoScopri il nostro HydroGene! ... in idrogeno e ossigeno in un processochiamatoelettrolisi che utilizzaenergierinnovabili. La catena del valoredell'idrogeno "verde" inizia quindi anche prima della sua produzioneeffettiva. Pepperl+Fuchsoffreun'ampiagamma di componenti che ottimizzano ...
1-10/925Elementi per pagina:
Nessun risultato trovato?
Suggerimento: usa il carattere * prima del tuo termine di ricerca, modifica la tua ricerca, verificare i termini di ricerca per gli errori ortografici, contattaci per le tue specifiche richieste.